It was brought to our attention when cloning radios for the Middle Mamm fire in Rifle, Colorado that we had cloned from a Bendix King Model KNG P150-G2, Running version 5.6.0A as well as a P150 Version 5.5.0E to a Bendix King Model DPH, that the User Code Guard was turned on in the CH00 Global Settings of the DPH when that was unintended. This problem has not occurred for us when cloning with a Model KNG 150S. In addition if that DPH radio is used to clone other radios of the Legacy BK models, that those radios suffer the same deficiency or malfunction until it's fixed by turning off the CH00 setting in EACH affected radio or recloning using an unaffected Legacy radio. Upon discussion, we learned that this was a major issue on the 416 and several other fires of 2018 and that it took several days and re-clones to get this "virus" out of the radio network. The BK cloning manual and the cloning instruction manual available on the NIICD website suggests that the scan toggles are in the off position prior to scanning but this has no effect on this problem. |